ARMY TM 9-2815-257-24
AIR FORCE TO 38G1-128-2
MARINE CORPS TM 10155A/2815-24/3
3-24
3-16. AIR CLEANER ASSEMBLY MAINTENANCE - cont.
1.
Do not clean air filter element. Do not tap or hit to remove dirt. If element is clogged or dirty, replace it.
2.
Clean electrical connection studs on air heaters with a stiff wire brush.
3.
Clean remaining components with cleaning solvent and a clean rag. Allow to air dry.
C. INSPECTION.
1.
Inspect cover (1, Figure 3-8), housing (2), adapters (6, 12), and air intake duct (15) for cracks, dents, or
corrosion. Replace component if damaged to the extent that it will effect proper operation of the air
filtering system.
2.
Inspect air heaters (8) for obvious damage. Replace if damaged is suspected.
3.
Inspect gaskets (11, 17, 20) for cuts, tears, or deformation. Replace if damaged or deformed.
D. INSTALLATION.
1.
If removed, install air intake duct (15, Figure 3-8) and gasket (20) using two screws (19). Install studs
(18).
2.
Install adapter (12) and gasket (17) using three nuts (16).
3.
Install adapter (6), air heaters (8) and gaskets (11) using four screws (13) and washers (14). Connect
electrical wire leads to heaters using nuts (9) and washers (10).
4.
Install filter housing (2) using three screws (7). Install filter element (5) into housing.
5.
Install cover (1) onto housing (2) and secure using wing nut (3) and washer (4).
|
|