ARMY TM 9-2815-259-24 AIR FORCE TO 38G1-125-2 MARINE CORPS 09249A/09246A-24 5-31 NOTE Orientation of pumping plungers is important.  Ensure that long and short pumping plungers are installed in correct orientation. (16)   Remove rotor (86, Figure 5-1) from fixture (16313).  Install pumping plungers (Figure 5-38), refer to Figure 5-38 for correct orientation. FIGURE 5-38.  PUMPING PLUNGER INSTALLATION. (17)   Install cam roller shoes (1, Figure 5-39) and cam rollers (2) on rotor (3). (18)   Install leaf springs (4) and adjusting screws (5).  Bottom screws, then back out one full revolution. FIGURE 5-39.  INSTALLING ROLLERS AND SHOES (TYPICAL)


 