ARMY TM 9-2815-259-24
AIR FORCE TO 38G1-125-2
MARINE CORPS 09249A/09246A-24
3-4
TABLE 3-2. UNIT TROUBLESHOOTING
(Sheet 1 of 11)
Not OK
Not OK
OK
OK
Not OK
ENGINE FAILS TO CRANK
Test for defective starter
solenoid
(refer to paragraph 3.9.2).
Replace starting motor
(refer to paragraph
3.9.2).
Test for defective starting
motor
(refer to paragraph 3.9.2).
Notify next higher
level of maintenance.
Notify next higher level
of maintenance.
Perform end item troubleshooting
procedures (refer to TM
9-6115-671-14 or other applicable TM).
Engine fails to crank.
Not OK
OK
STARTER OPERATES BUT ENGINE
DOES NOT TURN OVER.
Notify next higher
level of maintenance.
Remove starter (refer to paragraph
3.9.2) and check for worn or
broken starter pinion gear.
Repair or replace starter
(refer to paragraph 3.9.2).
Verify that engine is not
seized.
Starter operates but engine
does not turn over.
Notify next higher
level of maintenance.
OK
|
|
|
|