ARMY TM 9-6115-666-13&P
AIR FORCE TO 35C2-3-505-1
Table 2-2. Operator Preventive Maintenance Checks and Services
for AN/MJQ-1612 andAN/MJQ-1632
Item
Interval
Location
Procedure
Not Fully Mission Capable if:
No.
Item to Check/Service
GENERATOR SET -
continued
25
Before
OVERFLOW BOTTLE
a. Check overflow bottle for
Class III leaks. Coolant level is
leaks or missing parts
below cold line.
b. Check coolant level.
WARNING
Exhaust discharge contains deadly gases. DO NOT operate generator set
in enclosed areas unless exhaust is properly vented outside. Severe
personal injury or death due to carbon monoxide poisoning could result..
Muffler or exhaust system
26
Before
EXHAUST SYSTEM
a. Check muffler (16) for leaks
damaged or leaking.
and exhaust system for
corrosion, damaged or missing
parts.
Clogged element is indicated
27
Before
AIR CLEANER
Inspect air cleaner assembly
or piping and connections are
ASSEMBLY
(17) and piping for loose or
loose
damaged connections. Check
restriction indicator for clogged
element
WARNING
Battery acid can cause burns to unprotected skin.
WARNING
Batteries give off flammable gas. Do not smoke or use open flame when
performing maintenance. Flames and explosion could result in personal
injury or death.
28
Before
BATTERIES
Check electrolyte level
29
Before
BATTERY CABLES
Inspect cables and connectors
Cables are loose, missing
(18) for corrosion, loose,
parts
damaged or damaged or
missing.
2-21


 