NOTES:
1. UNLESS OTHERWISE SPECIFIED, ALL INSIDE BEND RADI SHALL BE .19
2. WELDING AND INSPECTION SHALL BE IN ACCORDANCE WITH AWS D1.2. INSPECTION SHALL BE
VISUAL. 5X MAGNIFICATION SHALL BE USED TO EVALUATE ANY AREAS QUESTIONED BY INITIAL
VISUAL EXAMINATION
3. BOND SHEET, FIND NO. 2 AND 3, TO SHEET, FIND NO. 1, USING ADHESIVE, FIND NO. 6
4. LOCATE STRAP FASTENER LOOP, FIND NO. 4, AS SHOWN AND ASSEMBLED WITH RIVETS, FIND
NO. 5. USE LOOP AS TEMPLATE TO PROVIDE HOLES IN ACCORDANCE WITH 13217E1061, CLASS
3
5. TREAT AND PAINT IN ACCORDANCE WITH MIL-T-704, TYPE G, EXCEPT SURFACES COVERED BY
SHEET, FIND NO. 2 AND 3
6. MARK IN ACCORDANCE WITH MIL-STD-530, METHOD OPTIONAL
Figure H-1. Cover, Switch Box (Sheet 2 of 2).
H-3