ARMY TM 9-6115-666-13&P
AIR FORCE TO 35C2-3-505-1
NOTES:
1. INSULATION COLORS, IN ACCORDANCE WITH WIRE LIST, SHALL BE INCLUDED AS PART OF THE
ORDERING DATA.
2. TERMINALS SHALL BE INSTALLED IN ACCORDANCE WITH MIL-STD-454, REQUIREMENTS 19.
3. EACH INSULATED CONDUCTOR END SHALL BE STRIPPED AS NOTED WITH THEIR INDIVIDUAL
STRANDS TWISTED TOGETHER, SOLDER COATED FOR A LENGTH OF .12 FROM END USING
SOLDER, FIND NO. 6.
4. REMOVE BRAID FROM GROUND WIRES (4 AWG), TWIST TOGETHER AND INSTALL TERMINAL LUG,
FIND NO. 5 AS SHOWN.
5. AT PIGTAIL END OF CABLE THE FOUR 4 AWG GROUNDING CONDUCTORS SHALL BE TWISTED
TOGETHER, STARTING AT THE JACKET, CONDUCTORS SHELL BE SOLDER COATED FOR A
LENGTH OF .25 FROM END, USING SOLDER, FIND NO. 6.
6. HOT STAMP "97403-13230E4564-( )" WITH APPROPRIATE DASH NO. AND "W( ) IN TWO PLACES
(180 APART) ON INSULATION SLEEVING, FIND NO.  2, IN ACCORDANCE WITH MIL-E-60903.
LOCATE APPROXIMATELY AT MIDPOINT ON -1 AND BOTH ENDS OF CABLE SHIELD ON -2.
7. HOT STAMP TERMINAL DESIGNATION AS SHOWN IN WIRE TABLE IN TWO PLACES (180 APART)
ON INSULATION SLEEVING, FIND NO. 1 AND 4, IN ACCORDANCE WITH MIL-M-60903.
Figure H-6. Cable Assembly W1 and W2 (Sheet 2 of 2).
H-18


 