SPECIFICATIONS
ELECTRICAL SWITCHES
5N8597 Contactor (Coolant)
Switch operates when temperature increases
to........................................98.30.6C (2081F)
7N5946 Pressure Switch
Circuit 1: normally closed
Circuit 2: normally open
With an increase in pressure, circuit 1 opens and
circuit 2 closes at ...........................145 kPa (21 psi) max.
With a decrease in pressure, circuit 2 opens and
circuit 1 closes at ........................... 7520 kPa (113 psi)
9D7032 Pressure Switch,
With an increase In pressure; switch closes
at .................................................. 51735 kPa (755 psi)
With a decrease in pressure, switch opens
at................................................ 41535 kPa (60 45 psi)
NOTE: FOR TORQUE VALUES NOT GIVEN, SEE THE FIRST
PAGE OF SPECIFICATIONS FOR GENERAL TIGHTENING TORQUES