Custom Search
 
  
 
TM   5-2815-241-34&P FUEL PUMP CALIBRATION - CONTINUED ACTION LOCATION ITEM REMARKS MOUNTING  PUMP  TO  TEST  STAND  -  CONTINUED 10.  Test  stand  (1) Fuel  input  hose  (2) 11. 12. 13. Fuel  suction Install  from  test  stand  fuel  outlet  connector hose  (5) (6)  to  test  stand  fuel  return  connector  (7). Leakage   accumulator Install to no. 1 accumulator cam (9) from hose  (8) test  stand  leak  test  connector  (10). 1/4-inch  (6.35  mm) Connect from small fitting (12) on fuel pump flexible  hose  (11) (13)  to  auxiliary  return  connector  (14). Install  from  test  stand  fuel  input  connector (3) to input discharge fitting (4). T A     2 4 2 6 1 8 2-336


 