TM 5-2815-241-34&P
FUEL PUMP CALIBRATION - CONTINUED
LOCATION
ITEM
ACTION
REMARKS
6. Test stand (2)
7.
8.
9.
1/4-inch (6.35 mm)
Connect from no. 2 manifold vacuum gage
clear manifold
(12) to 1/4-inch (6.35 mm) adapter (13)
hose (11)
on pump inlet adapter assembly (7).
Pump discharge fit-
ting assembly (14)
Fuel pressure
hose (16)
1/4-inch (6.35 mm)
flexible hose (18)
Install in pump fuel shutoff solenoid
valve (15).
Install from test stand pressure gage outlet
(17) to pump discharge fitting
assembly (14).
Install 1/4-inch (6.35 mm) flexible hose
(18) from test stand lube pressure connec-
tor (19) to test stand lube return
connector (20).
T A 2 4 2 5 6 1
2-335
|
|
|
|