TM 5-2815-241-34&P
ANEROID CONTROL VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY - CONTINUED
6. Aneroid control
valve (1)
7.
8.
9.
Bellows washer (2)
bellows (3), piston
(4), and spring (5)
Take off.
Side control
Using 1/4-inch flat-tip screwdriver, pry
cover (6)
out.
Bellows actuating
shaft (7), shaft
valve (8), and pre-
formed packing (9)
a.
b.
Check valve (10),
gasket (11), and
air filter (12)
a.
b.
C.
Discard side cover.
Lift up bellows actuating shaft and pull
out shaft valve.
Take off packing.
Discard.
Using 7/8-inch open-end wrench, un-
screw check valve and take out.
Take off gasket.
Discard gasket.
Using 7/16-inch box-end wrench, un-
screw air filter and take out.
CLEANING
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear safety goggles and gloves
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and
do not breathe vapors. Do not use near open flame or excessive heat. Flashpoint for
type #1 drycleaning solvent is 100oF (38°C) and for type #2 is 138°F (59°C). If you
become dizzy while using solvent, get fresh air immediately, and get medical aid. if
contact with eyes is made, wash your eyes with water, and get medical aid immediately.
Failure to observe these precautions could cause serious injury or death to personnel.
NOTE
For general cleaning procedures, see General Maintenance Instructions, page 2-3.
INSPECTION
10.
Bellows cover (10)
Check for cracks, chips, or warpage.
Discard if cracked, chipped, or
warped.
2-400
|
|