TM 5-2815-241-34&P
ANEROID CONTROL VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY
1. Aneroid control
valve (1)
Pipe plugs (2 and 3)
2.
Tubing nut (4) and
Using 9/16-inch box-end wrench, loosen
tubing (5)
and take off.
3.
Lead seal (6) three
screws (7) three
lockwashers (8)
and lock wire (9)
4.
5.
Bellows cover (10)
Screw (11) and
Using 7/16-inch box-end wrench, unscrew
lockwasher (12)
and take off.
a.
Using 3/16-inch hex wrench, unscrew
and take out.
b.
Drain oil into drain pan.
a.
Using diagonal-cutting pliers, cut lock
wire and take off.
b.
Using 7/16-inch box-end wrench, un-
screw and take out.
Discard lockwashers and lock wire.
Using plastic-faced hammer, tap gently and
take off.
Discard lockwasher.
T A 2 4 2 6 0 4
2-399
|
|