TM 9-2520-272-34&P
4-9. REMOVE CONVERTER ELEMENT
13
14
15
16
17
18
(SHEET 4 OF 5)
NOTE
COMPONENTS
Stator is removed from transmission with
assembled parts inside retained by two
retaining rings
Remove stator (14) from transmission.
REPAIR: Refer to paragraph 4-32 to disassemble
the stator group of components.
Remove seal ring (15) from converter pump assembly
(16).
Using chisel and ball peen hammer, bend tabs on ends
of four locking strips (17) away from heads of eight
bolts (18).
CAUTION
When holding pry bar between stud and input
housing wall, use only enough force to keep
pump from rotating while removing bolts.
Too much force on pry bar can damage input
housing wall or bend a stud.
Using end of pry bar between a stud (19) and the input
housing wall, hold pump (16) so that it cannot turn.
Using a 1/2 inch socket, remove eight bolts (18) that
hold locking strips (17) and retainers (20) to pump (16).
Remove four locking strips (17) and two retainers (20).
Go to Sheet 5
4-38
Para. 4-9, Task 1
|
|