TM   9-2520-272-34&P 4-9.   REMOVE   CONVERTER   ELEMENT 13 14 15 16 17 18 (SHEET  4  OF  5) NOTE COMPONENTS Stator   is   removed   from   transmission   with assembled   parts   inside   retained   by   two retaining    rings Remove   stator   (14)   from   transmission. REPAIR:  Refer   to   paragraph   4-32   to   disassemble the   stator   group   of   components. Remove   seal   ring   (15)   from   converter   pump   assembly (16). Using   chisel   and   ball   peen   hammer,   bend   tabs   on   ends of   four   locking   strips   (17)   away   from   heads   of   eight bolts   (18). CAUTION When   holding   pry   bar   between   stud   and   input housing   wall,   use   only   enough   force   to   keep pump   from   rotating   while   removing   bolts. Too  much  force  on  pry  bar  can  damage  input housing   wall   or   bend   a   stud. Using   end   of   pry   bar   between   a   stud   (19)   and   the   input housing   wall,   hold   pump   (16)   so   that   it   cannot   turn. Using   a   1/2   inch   socket,   remove   eight   bolts   (18)   that hold   locking   strips   (17)   and   retainers   (20)   to   pump   (16). Remove   four   locking   strips   (17)   and   two   retainers   (20). Go   to   Sheet   5 4-38 Para.  4-9,  Task  1


 