4-9. REMOVE CONVERTER ELEMENT COMPONENTS
(SHEET 5 OF 5)
19
20
21
22
NOTE
When sling is attached to three studs at
approximately equal distances apart, there
will be seven studs between sling lugs in two
places and eight studs between sling lugs in
one place.
Place three sling lugs over studs (19) located equal
distances apart on the pump (16) and install three
5/16-24 hex nuts (21) and washers (22) finger tight.
Using plastic faced hammer, tap on pump assembly
(16) while pullin up on pump with sling. Remove
pump assembly (16).
Remove three nuts (21) and washers (22) and sling
from pump (16).
Remove converter pump gasket (23) from inside
input housing assembly (24).
FOLLOW-ON PROCEDURE: Install converter element
components Refer to paragraph 4-14.
End of Task 1
Para. 4-9, Task 1