TM 9-2520-272-34&P
4-17.
REMOVE TRANSMISSION FROM MAINTENANCE STAND
(SHEET 4 OF 7)
10 Using two-leg sling, attach sling hooks to left lifting bracket (19) and right lifting bracket
(20).
11
12
13
14
Rotate transmission, input housing upward.
using hoist, one soldier raise three-leg sling until cables are tight. Maneuver hoist and
maintenance stand until all three cables are uniformly tight, ready to receive full weight of
transmission (21).
NOTE
When removing bolts (22), use hoist as necessary tO take tension off bolts.
Using 3/4 inch socket, other soldier remove three 1/2-32 x 2 inch bolts (22) and washers
(23) holding bottom of transmission (21) to adapter plate.
Move maintenance stand away from transmission (21).
Go to Sheet 5
4-76
Para. 4-17, Task 1
|
|