2-9. Starting Procedures. (figure 2-2)
a.
b .
c.
d.
e.
f.
g .
h.
i.
j .
Open fuel shutoff valve (1) on fuel filter (2).
Rotate choke control lever (3) counterclockwise and close choke.
On models 1A08-3 and -4, place throttle control (4) approximately 1/4 in. from idle position.
On models 1A08-3 and -4, set ignition switch (5) to RUN position.
On models 1A08-3, -4, set inlet temperature control as follows:
(1)
(2)
(3)
Above 50°F (10°C) push in handle (6).
Between 50-25°F (10° (-4)°C), place handle (6) in center position.
Below 25° (-4°C) pull out handle (6).
W A R N I N G
Operation of the equipment presents a noise hazard to personnel in the area. The noise
level exceeds the allowable limits for unprotected personnel. Wear ear muffs or ear plugs
which were fitted by a trained professional.
Serious eye injury can result from the starting rope knot. Wear eye protection when pull
starting engine.
Wind starting rope clockwise around starter flange (7) and pull briskly.
When the engine has started, rotate the choke control lever (3) clockwise until the choke is fully opened,
and the engine will continue to run.
N O TE
It maybe necessary on models 1A08-3 and -4 to rotate the throttle control
counterclockwise to obtain a smooth idle.
Allow engine to warm-up for at least 3 minutes.
On models 1A08-3 and -4, after warm-up, move throttle control counterclockwise to the full governed
position.
Apply end item load. Refer to End Item Operators Manual.