ARMY  TM  9-2805-262-14 AIR  FORCE  TO  38G2-90-1 NAVY  NAVFAC  P-8-613-14E Table 2-1. Operator Preventive Maintenance Checks and Services (PMCS) (cont). B - Before D - During A - After Interval Item Item to be Inspected Equipment  is  Not No. B D A Procedure Ready/Available   If 2 l l l AIR CLEANER SERVICE INDICATOR Check  indicator,  and  notify  unit  maintenance Indicator is in the red area. when indicator is in the red area. 3 l STARTER ROPE ASSEMBLY Inspect starter rope for cuts or signs of fraying. Section  Ill.  OPERATION  UNDER  USUAL  CONDITIONS Paragraph Page 2-9 Starting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2-7 2-10 Stopping Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2-8 2-9. Starting Procedures. (figure 2-2) a. b. c. d. e. Open fuel shutoff valve (1) on fuel filter (2). Rotate  choke  control  lever  (3)  counterclockwise  and  close  choke. On models 4A032-1 (serial nos. G001001 through G004004), -2, -3, -4 place throttle control (4) approximately  1/4  in.  from  idle  position. On models 4A032-1 (serial nos. G001001 through G004004), -2, -3, -4 set ignition switch (5) to RUN position. On models 4A032-1 (serial nos. G001001 through G004004), -2, -3, -4 set inlet temperature control as follows: (1) Above 50°F (10°C) set handle (6) to SUMMER position. (2) Between 50-25°F (10° (-4)°C), place handle (6) in center position. (3) Below 25° (-4°C) set handle (6) to WINTER position. 2-7


 