TM9-2815-202-34
4-10. AIR BOX HEATER REPLACEMENT (Cont)
IGNITION COIL
a. Removal
(1)
(2)
(3)
(4)
Disconnect high tension lead (28)
from ignition coil (40). Remove lead.
Disconnect wiring harness connector
(41) from ignition coil (40).
Remove bolt (42), Iockwasher (43),
and flat washer (44) securing bracket
(45) and ignition coil (40) to air inlet
housing. Remove coil and bracket as
an assembly. Discard Iockwasher.
Remove bolt (46), nut (47), and
Iockwasher (48) from bracket (45).
Remove ignition coil
Discard Iockwasher.
(40) from bracket.
c. Cleaning/inspection
WARNING
l
l
(1)
(2)
Dry cleaning solvent P-D-680
goggles and gloves and use
is toxic and flammable. Wear protective
only in well-ventilated areas. Avoid
contact with skin, eyes, and clothes. Dont breathe vapors. Do not use
near open flames or excessive heat. The flash point is 100oF-138oF
(38°C-50oC). If you become dizzy while using cleaning solvent, get
medical aid. If contact with eyes is made, wash your eyes with water
and get medical aid immediately.
Compressed air used for cleaning purposes wiII not exceed 30 PSI.
Use only with effective chip guarding and personal protective
equipment (goggles/shield, gloves etc.).
Clean outside surface with cleaning solvent and dry with compressed air.
Inspect ignition coil for oil seepage or damage to electrical connectors.
4-28
|
|