Custom Search
 
  
 
TM9-2815-202-34 c.   Cleaning/Inspection WARNING l Dry  cleaning  solvent  P-D-680  is  toxic  and  flammable. goggles  and  gloves  and  use  only  in  a  well-ventilated Wear  protective area. Avoid contact  with  skin,  eyes,  and  clothes  and  don’t  breathe  vapors.  Do  not use  near  open  frames  or  excessive  heat.  The  flash  point  is  100°F-138°F (38°C-50oC).  If  you  become  dizzy  while  using  cleaning  solvent,  get medical  aid.  If  contact  with  eyes  is  made,  wash  your  eyes  with  water and  get  medical  aid  immediately. l Compressed  air  used  for  cleaning  purposes  will  not  exceed  30  PSI. Use  only  effective  chip  guarding  and  personal  protective  equipment (goggles/shield,   gloves,   etc). (1) Clean all parts with dry cleaning solvent and dry with compressed air. (2)  Inspect  adaptor,  pipe,  and  shell  for  cracks,  pitting, (3)  Inspect  filter  element  for  cuts,  tears,  or  damaged. d. Assembly or damage. (1) (2) Install  gasket  (16)  and  breather  pipe  (15)  onto  adaptor  (12).  Secure  with  two  lockwashers (14) aid two bolts (1 3). Torque bolts to 30-35 lb-ft (41-47 N-m). Install filter element (10) and shell (11) onto adaptor (12) and secure with spacer (9), fiat washer (8), and bolt (7). Torque bolt to 30-35 lb-ft (41-47 N-m). e.  installation (1) (2) Install gasket (6) onto breather assembly (5). Position  breather  assembly  (5)  onto  flywheel  housing and secure with two bolts (1), bolt (2), three bolts (3), and six lockwashers (4). Torque bolts to 30-35 lb-ft (41-47 N-m). 6-27


 