TM9-2815-202-34
c. Cleaning/Inspection
WARNING
l
Dry cleaning solvent P-D-680 is toxic and flammable.
goggles and gloves and use only in a well-ventilated
Wear protective
area. Avoid
contact with skin, eyes, and clothes and dont breathe vapors. Do not
use near open frames or excessive heat. The flash point is 100°F-138°F
(38°C-50oC). If you become dizzy while using cleaning solvent, get
medical aid. If contact with eyes is made, wash your eyes with water
and get medical aid immediately.
l
Compressed air used for cleaning purposes will not exceed 30 PSI.
Use only effective chip guarding and personal protective equipment
(goggles/shield, gloves, etc).
(1) Clean all parts with dry cleaning solvent and dry with compressed air.
(2) Inspect adaptor, pipe, and shell for cracks, pitting,
(3) Inspect filter element for cuts, tears, or damaged.
d. Assembly
or damage.
(1)
(2)
Install gasket (16) and breather pipe (15) onto adaptor (12). Secure with two lockwashers
(14) aid two bolts (1 3). Torque bolts to 30-35 lb-ft (41-47 N-m).
Install filter element (10) and shell (11) onto adaptor (12) and secure with spacer (9), fiat
washer (8), and bolt (7). Torque bolt to 30-35 lb-ft (41-47 N-m).
e. installation
(1)
(2)
Install gasket (6) onto breather assembly (5).
Position breather assembly (5) onto flywheel housing
and secure with two bolts (1), bolt (2), three bolts (3),
and six lockwashers (4). Torque bolts to 30-35 lb-ft
(41-47 N-m).
6-27
|
|