MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
16. INOPERATIVE GLOW PLUG SYSTEM AT LOW AMBIENT TEMPERATURE
(MODEL 7063-7391 )
Step 1.
Step 2.
Step 3.
Step 4.
END OF TEST
Check batteries for low or no voltage (Refer to applicable vehicle type-20
maintenance manual for test and services).
Glow plug wait/pilot lamp does not light.
a. Ambient temperature above 50oF.
b. Check wait/pilot lamp bulb (Refer to applicable vehicle type-20 maintenance
manual for test and services).
c. All four paired glow plug connector pins short circuited (Refer to applicable
vehicle type-20 maintenance manual for test and services).
d. Controller switching device is open (Refer to Para 5.1-8 to remove and replace
glow plug controller).
Glow plug wait/pilot lamp stays lit.
Fault in glow plug controller (Refer to Para 5.1-8 to remove and replace glow plug
controller).
Glow plug wait/pilot lamp flashes during preglow and afterglow periods.
Glow plug controller short circuit protection fuse(s) failed. (Refer to applicable
vehicle type-20 maintenance manual for test and services).
Change 1
2-19/2-20 Blank
|
|
|
 |