TM9-2815-202-34
8-17. CRANKCASE PRESSURE TEST
Thistaskcovers: Testing
l
INITIAL SETUP
MODELS
EXPENDABLE/DURABLE SUPPLIES
I All
Food coloring (App C, Item 19)
TOOLS AND SPECIAL TOOLS
*
General mechanics tool kit (App B, Item 96)
Manometer (App B, Item 64)
Nonmetallic tubing (App B, Item 98)
Turbocharger Inlet shield (App B, Item 81)
Testing
a.
b.
c.
d.
e.
f.
9.
Remove one tube connector (1) from manometer (2) by rotating in counterclockwise direction.
Turn other tube connector (3) clockwise until fully engaged and then back out one full turn.
Add five drops of food coloring to one pint of distilled water and mix.
Add colored solution (4) to manometer (2) until liquid level is opposite zero mark on manometer
l
scale with manomete~ in a vertical posifion.
NOTE
Eliminate air bubbles by tilting
manometer and gently tapping
manometer.
Install tube connector (1) until fully
engaged and then back out one full turn.
Remove oil level gage and tube from oil
pan. Install hose adaptor (5) in oil pan.
Connect hose (6) to adaptor (5) and tube
connector (1). Mount manometer in vertical
position. Close manometer tube connector
attached to hose.
.
8-42
Change 1
|
|