Custom Search
 
  
 
TM 9-2815-220-24
INTAKE AND EXHAUST VALVE TIMING PROCEDURE
0035 00
TIMING CHECK (Continued)
1. Turn crankshaft until valves (7,8) are closed
and camshaft lobes (9) are pointing towards
7
cylinder base as shown.
NOTE
Standard intake valve clearance is
set to 0.010 inch (0.254 mm); when
8
checking valve timing, this
clearance is increased to 0.100 inch
9
(2.54 mm).
2. Adjust intake valve (8) clearance for timing check (0.100 inch, or (2.54 mm).
a. Loosen intake valve adjusting screw lock nut (10).
b. Turn valve adjusting screw (11) until clearance between valve adjusting screw pad (12)
and valve stem is 0.100 inch using thickness gauge blade (13) (item 57, WP 0176). Gauge
blade must move through clearance with a slight drag.
c. Check position of valve adjusting screw pad (12) to make sure seat is flat on valve stem.
d. Torque lock nut (10) to 200-225 inch-pounds (22.6-25.4 Nm) after correct adjustment is
made. Make certain setting has not changed after tightening lock nut (10).
12
10
11
8
13
WP 0035 00-4

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business