Custom Search
 
  
 
TM 9-2815-220-24
FUEL/WATER SEPARATOR OPERATION TESTS
0042 00
TESTS (Continued)
2. Test automatic drain valve (13) operation (continued):
e. Place metal container under drain valve tube (18).
f. Disconnect engine electrical harness (19) connector from control box (20).
g. Connect jumper wire (21) (item 9, WP 0177) from second metal container to negative (-)
side of 24-volt dc power source.
h. Connect test harness connector (22) (item 8, WP 0177) to control box receptacle.
i. Connect red wire (23) to positive (+) side of 24-volt dc power source.
j. Connect black wire (24) to negative (-) side of 24-volt dc power source.
k. Fill second metal container with water.
22
19
20
23
24
18
13
21
WATER
FUEL
WP 0042 00-5

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business