Custom Search
 
  
 
TM 9-2815-220-24
FUEL/WATER SEPARATOR OPERATION TESTS
0042 00
AFTER TESTS (Continued)
6. Install upper and lower sensor probes (14, 15).
a. Place metal container under manual drain valve (12) outlet, open valves and allow fuel to
empty into container. When drained, close valve and remove container.
Metal Container
12
b. Remove two pipe plugs (17) from sensor probe (14, 15) holes.
c. Install sensor probe fittings (16).
d. Install both probes (14, 15) in their proper locations in fuel/water separator (1).
16
17
14
16
1
1
17
15
WP 0042 00-10

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business