Tweet |
Custom Search
|
|
|
||
TM 9-2815-220-24
STARTER MOTOR REPLACEMENT
0049 00
REMOVAL
NOTE
Engine models with 650 ampere generators have two ground straps.
Engine models with 300 ampere generators have one ground strap.
1. Disconnect starter ground wires.
a. Remove hexagon nut (4) and lock washer (5) to disconnect ground strap(s) (6) and two
wiring harness cables (7).
b. Install hexagon nut (4) and lock washer (5) on starter terminal.
c. Remove screw (8) with flat washer (9) to remove ground strap(s) (6) from starter support
bracket (10). Retain ground strap(s) for installation.
2. Disconnect starter positive cables.
a. Remove hexagon nut (11) and lock washer (12) to disconnect starter positive cables (13)
and starter low voltage protective module electrical lead (14).
b. Install hexagon nut (11) and lock washer (12) on starter (battery) terminal.
c. Remove nut (15) with lock washer (16) from starter to disconnect low voltage protective
module electrical lead (17).
d. Install nut (15) and lock washer (16) on starter terminal.
4
5
17
6
7
16 15
11
12
14
13
6
10
8, 9
WP 0049 00-2
|
||