Custom Search
 
  
 
TM 9-2815-220-24
GENERATOR REPLACEMENT (650 AMPERE)
0051 00
REMOVAL (Continued)
NOTE
Early model Honeywell generators were installed with a retaining
strap to hold the generator in the cradle. It has been determined that
the strap is not required. If the cradle that you removed has the
retaining strap, remove and discard it.
If your generator does not have a retaining strap, skip to "Exchange Parts."
17. Remove retaining strap (36).
a. Loosen T-bolt (37) and remove cradle (24) from generator (28). Using drive punch, drive
roll pins (38) attaching strap (36) ends to cradle (24) and discard strap and roll pins.
28
36
36
37
24
38
WP 0051 00-7

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business