Custom Search
 
  
 
TM 9-2815-220-24
GENERATOR REPLACEMENT (650 AMPERE)
0051 00
EXCHANGE PARTS
(Ormat Illustrated - Honeywell Similar)
NOTE
It will help when exchanging fittings to have both generators side by
side to orient the fittings the same in the replacement generator.
1.
Disconnect drain hose (39) from front of tee (20) and from drain elbow (40).
2.
Remove tee (20) and drain elbow (40) and install in replacement generator. Orient both
fittings the same as they were initially.
3.
Connect drain hose (39) to front of tee (20) and to drain elbow (40) in replacement generator.
4.
Remove oil inlet elbow (14) with O-ring (41). Discard O-ring. Install inlet elbow (14) with
new O-ring (14) (item 73, WP 0175) on replacement generator orienting the elbow the same as
it was.
CAUTION
Orifice fitting (42) must be in place. Damage to engine may occur if
orifice fitting is not in place.
5. Remove vent fitting (16) and orifice fitting (42) and install in replacement generator.
6. Remove oil return fitting (18) with O-ring (43). Discard O-ring. Install fitting (18) with new
O-ring (43) (item 143, WP 0175) on replacement generator.
18
43
42
16
20
40
39
41
14
WP 0051 00-8

 