Custom Search
 
  
 
TM 9-2815-220-24
GENERATOR REPLACEMENT (300 AMPHERE)
0052 00
INSTALLATION
1. Apply silicone compound (item 34, WP 0173) to the inside of the generator boot (35) sealing
surface before installation.
2. Assure that six self-locking nuts (39) are started on generator mounting studs with clearance
allowed for generator (1) flange.
3. Loosely install generator boot (35) on generator (1) so that mounting access openings (A) are
exposed.
4. Position generator (1) so that large elongated openings in flange are aligned with mounting
nuts (39), then install generator.
a. Rotate generator (1) counterclockwise to end of travel and tighten six self-locking
nuts (39) using box wrench (item 137, WP 0176).
5. Loosely affix clamps (38), then position generator boot (35) so that outlet end aligns with
exhaust tube (37) and mounting access openings (A) are not exposed.
a. Secure generator boot with one hose clamp (36) at exhaust tube and two clamps (38) on
large diameter.
A (6 places)
36
35
1
39
38
38
37
36
35
1
WP 0052 00-7

 