Custom Search
 
  
 
TM 9-2815-220-24
WIRING HARNESS REPLACEMENT, STARTER, SMOKE GENERATOR, AND DUST
DETECTOR WITH LOW VOLTAGE PROTECTION MODULE TOP MOUNTED
(2CA, 2DA) (PART NUMBERS 11655454, 12314619, AND 12354468)
0060 00
INSTALLATION (Continued)
NOTE
For smoke generation systems with single-solenoid configuration,
harness installation instructions are covered in step 4.
For smoke generation systems with dual-solenoid configuration,
harness installation instructions are covered in step 3.
4. Harness installation with single solenoid smoke generator harness.
a. Install connector (42) at smoke generator solenoid (43).
b. Install ground lead (46) with screw (44) and new lock washer (45) (item 93, WP 0175).
c. Install loop clamps (49) with assembled washer screws (48).
d. Install tie wraps (47) (item 81, WP 0175) as needed.
48, 49
47
44, 45
46
43
42
WP 0060 00-20

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business