Custom Search
 
  
 
TM 9-2815-220-24
WIRING HARNESS REPLACEMENT, STARTER, SMOKE GENERATOR, AND DUST
DETECTOR WITH LOW VOLTAGE PROTECTION MODULE TOP MOUNTED
(2CA, 2DA) (PART NUMBERS 11655454, 12314619, AND 12354468)
0060 00
INSTALLATION (Continued)
5. Install starter wiring harnesses.
a. Install starter main power cable end connectors (62, 63) into mounting bracket (33).
Secure with four machine screws (27), new lock washers (28) (item 91, WP 0175), and
nuts (29).
b. Install low voltage protection module (32) onto mounting bracket (33) with two
screws (30) and new lock washers (31) (item 82, WP 0175). Make sure to secure ground
wire (53) with one module securing screw (30).
30, 31 (two places)
53
32
27, 28, 29 (four places)
33
62
63
27, 28, 29
(four places)
WP 0060 00-21

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business