Custom Search
 
  
 
TM 9-2815-220-24
STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT,
0061 00
LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726)
INSTALLATION (Continued)
NOTE
For smoke generation systems with dual-solenoid configuration,
harness installation instructions are covered in steps 4 and 5.
For smoke generation systems with single-solenoid configuration,
harness installation instructions are covered in steps 6 and 7.
4. Install smoke generator/dust detector leads (32, 33) and starter harnesses (27) on models with
dual-solenoid smoke generation system.
a. Install wiring harness connectors (27) into bracket (28) using four slotted head machine
screws (29), new lock washers (30) (item 91, WP 0175), and nuts (31).
b. Install retaining strap (24) on starter harnesses and secure bracket assembly using
two screws (25) with new lock washers (26) (item 92, WP 0175).
c. Install assembled washer screws (34), loop clamps (35) and tie wraps (36) (item 80,
WP 0175) as necessary securing dust detector (32) and smoke generation harness (33).
33
28
32
34, 35, 36
27
29, 30, 31 (four places)
24
25, 26 (two places)
WP 0061 00-18

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business