Custom Search
 
  
 
TM 9-2815-220-24
STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT,
0061 00
LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726)
INSTALLATION (Continued)
NOTE
For smoke generation systems with dual-solenoid configuration,
harness installation instructions are covered in steps 4 and 5.
For smoke generation systems with single-solenoid configuration,
harness installation instructions are covered in steps 6 and 7.
5. Install smoke generator harness (33) on models with dual-solenoid smoke generation system.
a. Install connectors at smoke generator solenoids (39).
b. Install harness (33) into loop clamp (38) securing with new self-locking nut (37) (item 33,
c. Install tie wraps (40) (item 80, WP 0175) as needed.
37
33
40
38
39
WP 0061 00-19

 