TM 9-2815-220-24
STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT,
0061 00
LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726)
INSTALLATION (Continued)
NOTE
For smoke generation systems with single-solenoid configuration,
harness installation instructions are covered in steps 6 and 7.
For smoke generation systems with dual-solenoid configuration,
harness installation instructions are covered in steps 4 and 5.
6. Install smoke generator/dust detector leads (33, 34) and starter harnesses (27) on models with
single-solenoid smoke generation system.
a. Install wiring harness connectors (27) into bracket (28) using four slotted head machine
screws (29), new lock washers (30) (item 91, WP 0175), and nuts (31).
b. Install retaining strap (24) on starter harnesses and secure bracket assembly using
two screws (25) with new lock washers (26) (item 92, WP 0175).
c. Install loop clamps (42), using assembled washer screws (41) as necessary to secure smoke
generator harness (33) and dust detector harness (32).
d. Install tie wraps (43) (item 81, WP 0175) as necessary.
28
41, 42, 43
32
27
24
41, 42, 43
33
25, 26
29, 30, 31
(two places)
(four places)
WP 0061 00-20

 