FUEL SUPPLY PUMP MOUNTING ADAPTER REPAIR/REPLACEMENT
0109 00
INSPECTION
All parts must be inspected with care. Replace parts if damage or wear exceeds allowable
limits.
1. See Work Package 0028 for Standard Inspection Procedures.
2. Check that studs (7,8,9) are not bent, stripped or otherwise damaged.
a. See Work Package 0028 for stud replacement procedures.
b. Refer to the following table for stud size and setting height.
Location
Stud Size and Length
Number
Setting Height
Required
inch (mm)
7
3/8-16(7/8) X 3/8-24(15/16) X 1-3/4
2
1-3/16 (30.1625)
8
3/8-16(7/8) X 3/8-24(15/16) X 1-3/4
6
1-1/16 (26.9875)
9
3/8-16(13/16) X 3/8-24(11/16) X 1-5/8
4
15/16 (23.8125)
7
8
6
4
10
8
9
3. Check that back-flow valve bracket (1) is not bent, cracked or otherwise damaged.
a. Replace bracket (1) if damaged.
4. Check mounting surface of both adapter (4) and damper
housing (10).
1
a. Look for scratches, nicks, or other damage that
would prevent gasket (6) from sealing.
(1) Polishing with crocus cloth (item 9, WP 0173)
wetted in cleaning solvent (item 8,
WP 0173) may repair minor imperfections.
(2) Replace adapter (4) or damper housing (10) if
damage cannot be repaired.