Tweet |
Custom Search
|
|
|
||
TM 9-2815-220-24
PTO COUPLING/FUEL PUMP DRIVE HOUSING REPAIR (2DR ONLY)
0111 00
INSPECTION (Continued)
3. Inspect studs (26 through 30).
a. Look for bent, stripped or otherwise damaged studs (26,27,28).
b. If any stud needs replacement, go to Work Package 0028 for standard instructions and
refer to the following table for stud size and setting height.
Location
Stud Size and Length
Number Required Setting Height
26
1/4-20(37/64) X 1/4-28(35/64) X 1-3/16
2
23/32
27
5/16-18(49/64) X 5/16-24(53/64) X 1-25/32
4
1-1/8
28
3/8-16(7/8) X 3/8-24(15/16) X 1-3/4
4
1-1/16
29
3/8-16(7/8) X 3/8-24(27/64) X 1-3/4
2
1-1/16
30
3/8-16(13/16) X 3/8-24(15/16) X 4-11/16
2
4-1/16
26
29
28
27
30
WP 0111 00-6
|
||