TM 9-2815-220-24
FUEL/WATER SEPARATOR CONTROL MOUNTING PLATE
REPLACEMENT
0121 00
CLEANING
1. See Work Package 0028 for Standard Cleaning Procedures.
INSPECTION
All parts must be inspected with care. Replace part if damage or wear exceeds allowable
limits.
1. See Work Package 0028 for Standard Inspection Procedures.
INSTALLATION
1. Install fuel/ water separator control mounting plate (1).
a. Apply a small amount of Lubriplate (item 23, WP 0173) to four bolts (2).
b. Position fuel/ water separator control mounting plate (1) onto engine block.
d. Tighten four bolts (2) to 13 to 15 foot-pounds (18-20 Nm), using torque wrench (item
127, WP 0176).
1
3
2
4
END OF WORK PACKAGE