TM 9-2815-225-34&P
3-13.
MOUNTING ENGINE ON MAINTENANCE STAND (Contd)
LOCATION/ITEM
ACTION
REMARKS
b. Draining
NOTE
Use separate containers for draining each system.
2.
Oil drainplug (6)
a. Remove from oil pan (13).
Allow oil to drain out.
b. Install on oil pan (13) when oil
stops draining.
WARNING
Do not perform fuel system procedures while smoking or within 50 ft (15.2 m) of sparks or
open flame. Diesel fuel is flammable and may explode. Failure to comply may result in
injury to personnel and/or damage to equipment.
3.
Fuel/water separator
a. Open.
Allow fuel to drain out.
drainvalve (4)
b. Close when fuel stops draining.
4.
Ether quick-start thermostat
a. Disconnect connector (8) from
wire harness connector (8)
thermostat (9).
and either quick-start
thermostat (9)
b. Remove from cylinder block
Drain coolant from cylinder
(12).
block (12).
5.
Oil cooler water drainvalve
Open.
Drain coolant from oil cooler.
(7)
6.
Thermostat housing
Open.
Provides air vent for draining
drainvalve (10)
thermostat housing.
7.
Ether quick-start
Install on cylinder block (12)
Do not tighten.
thermostat (9)
when coolant stops draining.
8.
Drainvalves (7) and (10)
Close when coolant stops draining.
c. Cleaning
9.
Dressed engine
a. Cover all openings with water-
assembly (1)
proof tape or suitable caps or plugs.
b. Clean all external parts
Ensure no foreign material
and outer surfaces.
enters the working parts of
engine.
c. Remove mud and dirt using
water under pressure.
WARNING
Approved solvents may be flammable and will not be used near open flame. Use only in
well-ventilated area. Failure to comply may result in injury to personnel.
d. Remove oil and grease using a
stiff brush and approved solvent.
3-12
|
|
|
|
Privacy Statement -
Copyright Information. -
Contact Us