TM 9-2815-225-34&P
3-63. FUEL PUMP TESTING AND CALIBRATION (Contd)
LOCATION/ITEM
ACTION
REMARKS
g. Governor Cutoff RPM Check
54.
Fast button (25)
Depress until pump speed is
Make sure flow control valve (37)
2100 rpm as indicated on
is open and selector valve (36)
tachometer (7).
is set at the ROTAMETER posi-
tion.
55.
Flow control valve (37)
Adjust to 470 pph.
Fuel pump throttle lever (48)
should remain in wide-open posi-
tion and be secured by a spring.
56.
Fast button (25)
While watching fuel pressure
Pressure should drop when
gauge (2), gradually increase
reading on tachometer (7) is
pump speed until pressure
between 2130 and 2150 rpm. If
drops slightly instead of
governor cutoff point (as indicated
rising.
by the tachometer) is not within
above limits, do steps 57 through
60. If governor cutoff point is
within limits, go to step 61.
3-488
|
|