TM 9-2815-226-34-1
d. Inspect cam follower lever rollers and pins.
(1) Drive out roll pin retaining cam roller pin to follo wer lever. Discard pin.
(2) Remove roller pin and roller.
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30 PSI
(207 KPA). USE ONLY WITH EFFECTIVE CHIP GUARDING AND PERSONAL
PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
MINERAL SPIRITS ARE POTENTIALLY DANGEROUS. AVOID PROLONGED OR
REPEATED CONTACT WITH SKIN. KEEP AWAY FROM FLAME OR EXCESSIVE
HEAT.
(3) Clean roller and roller pin with mineral spirits and dry with compressed air.
(4) Direct air through small oil passages in lever to clear of foreign matter.
CAUTION
IF ROLLERS SCORED OR GALLED, MAKE CAREFUL INSPECTION OF CAMSHAFT
LOBES FOR DAMAGE.
(5) Inspect cam rollers for scoring and galling. Discard if defects found.
3-216