(6) Mark insert for replacement if scored.
(7) Apply Prussian bluing to 0.625 in. (15.88 mm) check ball or new push tube ball.
(8) Insert check ball or push tube into follower lever insert.
(9) Remove ball or tube.
(10) Check bluing area in insert. Area must blue-in a minimum of 80 percent.
(11) Mark insert for replacement if blue-in specification not met.
NOTE
Use magnetic particle method to inspect follower lever for cracks.
(12) Apply coil magnetization with amperage at 300 to 500 with residual Magnaglo.
(13) Check follower lever for cracks. Illustration shows most likely area where cracks could occur.
(14) Discard lever if any cracks are found on lever.
3-215


 