Section XVII. FLYWHEEL HOUSING REPAIR
3-44. INSPECT FLYWHEEL HOUSING
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30
PSI (207 KPA).
USE ONLY WITH EFFECTIVE CHIP GUARDING AND
PERSONAL PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
P-D-680 SOLVENT IS POTENTIALLY DANGEROUS.  AVOID PROLONGED OR
REPEATED CONTACT WITH SKIN. KEEP AWAY FROM FLAME OR EXCESSIVE
HEAT.
a. Clean housing with solvent and dry with compressed air.
b. Visually inspect housing for cracks.
c. If cracked, replace housing.
d. Check starter mount pad threads for distortions.
e. If threads distort ed, mark for repair.
3-45. REPAIR FLYWHEEL HOUSING
NOTE
Repair of housing limited to re-threading of starter mount holes.
a. Determine size of threads.
b. With used tap, repair damaged thread.
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30 PSI
(207 KPA).  USE ONLY WITH EFFECTIVE CHIP GUARDING AND PERSONAL
PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
c. Blow out hole with compressed air.
d. Screw proper size capscrew into housing to check threads.
e. If distortion does not clear up, replace housing.
3-229


 