3-47. INSPECT ROCKER LEVER COVERS
a. Clean rocker lever cover.
(1) Scrape gasket material from sealing surface.
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30
PSI (207 KPA).
USE ONLY WITH EFFECTIVE CHIP GUARDING AND
PERSONAL PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
P-D-680 SOLVENT IS POTENTIALLY DANGEROUS. AVOID PROLONGED OR
REPEATED CONTACT WITH SKIN. KEEP AWAY FROM FLAME OR EXCESSIVE
HEAT.
(2) Clean cover in solvent and dry with compressed air.
b. Inspect rocker lever cover.
(1) Remove breather baffle retaining nuts and remove baffle on no. 3 cover.