d. Assemble shutoff valve assembly.
(1) Install new O-ring on override shaft and apply a light coat of lubricating oil on O-ring.
(2) Screw override shaft into valve housing until valve bottoms in bore.
(3) Using depth micrometer set at 0.118 in. (2.997 mm), check distance from fac e of valve housing to tip of
override shaft.
(4) If necessary, screw shaft out until it is 0.118 in. (2.997 mm) below face of valve housing.