i. Inspect turbine housing.
(1) Measure mount flange inside diameter (A). New part limit is 5.0543 in. (128.379 mm). Replace casing if dameter
i
exceeds 5.058 in. (128.473 mm).
(2) Measure casing depth (B). New part limit is 1.1935 in. (30.3149 mm). Replace housing if depth exceeds 1.202
in. (30.530 mm).
(3) Replace casing if turbine wheel contact marks are found.
(4) Check for crac ks in mounting flange or exhaust pipe attachment flange. Replace if cracked.