Tweet |
Custom Search
|
|
|
||
TM 9-2815-226-34-2
NOTE
Do not increase the total gasket thickness to more than 0.080 in. (20.32 mm). The
minimum total thickness must not be less than 0.014 in. (0.356 mm).
(a) Advance or retard injector timing as follows:
NOTE
Cam follower housing gaskets are available in four thickness; 0.006 0.008 in.
(0.152-0.203 mm); 0.014 0.020 in. (0.3550.508 mm); 0.002 0.024 in. (0.050-0.609
mm); 0.027 0.037 in. (0.685-0.939 mm). Refer to para 3-6 for cam follower gasket
removal and para 3-94j for gasket installation.
(b) Advance timing by increasing thickness of cam follower housing gaskets.
(c) Retard timing by decreasing thickness of cam follower housing gaskets.
3-425
|
||