Custom Search
 
  
 
TM 9--2815--247--34 0015 00--19 INTAKE AND EXHAUST VALVE AND METERING PUMP TIMING -- CONTINUED 0015 00 Adjust -- Continued 18. Rotate flywheel (8) counterclockwise, as viewed from the flywheel end, approximately 140° until “6L INT CLOSE 0.100 CLR” timing mark (20) aligns with timing mark (10), then rotate flywheel an additional 360° until “6L INT CLOSE 0.100 CLR” timing mark (20) aligns with timing mark (10) the second time. Figure 7 8 20 10 19. Remove retaining ring (27) from bevel gearshaft (28) on left bank. Discard retaining ring. Figure 10 28 27


 