TM 9--2815--247--34
0038 00--7
FLEXIBLE COUPLING SHAFT ASSEMBLY (METERING PUMP) REPAIR --
CONTINUED
0038 00
Assembly
1. Install new preformed packings (14 and 15) on hub (5) and install hub (5) into sleeve (4).
2. Install new preformed packing (16) on hub (12) and install hub (12) into sleeve (11).
NOTE
Plugs will be permanently installed when coupling is
greased. Refer to WP 0039 00.
3. Loosely install two new pipe plugs (17).
Figure 35
4
15
5
12
16
17
11
17
14
|
|
|
|