Custom Search
 
  
 
TM 9--2815--247--34 0049 00--2 METERING PUMP THROTTLE LINKAGE AND ASSOCIATED PARTS REPAIR -- CONTINUED 0049 00 Removal -- Continued 3.   Remove two screws (9), angle bracket (10), and spring (11) from metering pump (12). 4.   Disconnect and remove rigid connecting link (1) from metering pump (12) by removing cotter pin (13) and flat washer (14). Discard cotter pin. 5.   Disconnect and remove control rod assembly (5) from bell crank (15) by removing machine bolt (16), self--locking nut (17), and flat washer (18). Discard self--locking nut. 6.   Remove machine bolt (19) and self--locking nut (20) from governor control rod (21) at metering pump (12). Dis- card self--locking nut. 7.   Disconnect and remove governor control rod assembly (21) from bell crank (15) by removing machine bolt (22) and self--locking nut (23). Discard self--locking nut. Figure 48 1 20 19 17 18 16 5 15 10 12 11 9 13 14 12 21 22 23


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business