TM 9--2815--247--34 0015 00--9 INTAKE AND EXHAUST VALVE AND METERING PUMP TIMING -- CONTINUED 0015 00 Test -- Continued 19. If valve and fuel metering pump timing are correct, re--adjust intake valve clearance on cylinders 6R and 6L to 0.010 inch (.25 mm) following steps 8 through 11 and 14 through 17. 20. Install timing hole plug (5) on fuel metering pump (6). Figure 35 5 6 21. Apply a small amount of lubricant to 12 cap screws (1). 22. Install right and left bank access cover (3) and a new gasket (4) using six cap screws (1) and six flat washers (2). 23. Torque 12 cap screws (1) to 275--325 lb--in (31.1--36.7 NSm). Figure 10 1 2 3 4


 