INTAKE AND EXHAUST VALVE AND METERING PUMP TIMING --
CONTINUED
0015 00
Adjust -- Continued
4. Rotate flywheel (8) counterclockwise, as viewed from the flywheel end, approximately 230° until 6R INT CLOSE
0.100 CLR timing mark (19) aligns with timing mark (10).
Figure 7
19
8
10
5. Remove retaining ring (21) from bevel gearshaft (22) on right bank. Discard retaining ring.
Figure 10
21
22
|
|