TM 9-2815-250-24&P 3-19.   FLOW CONTROL VALVE ADJUSTMENT (continued). b. Remove  injector  line  fitting  (3),  O-ring  (4),  spring guide   (5),   shim   (6),   spring   (7),   gasket   (8),   and delivery  valve  (9)  from  injection  pump  outlet  port (10).  Discard O-ring and gasket. c. Install  fuel-testing  device  (13),  adapter  rod  (12), and indicator dial (11) in injection pump outlet port (10). d. Remove   three   screws   (18),   nut   (19),   mounting plate  (17),  and  gasket  (16)  from  crankcase  (14). Install    screw    (18)    on    auxiliary    drive    side    of mounting plate opening (15).  Discard gasket. 3-61


 